Air Leak Detector

The leak you can't hear
is the loss you can't measure.

Leaks in compressed air lines are silent. Your energy bill is not.

20–60kHz ultrasonic 550gram body 4.5hours in field
Ultrasonic Detection · 20–60 kHz

Four microphones,
one exact point.

The array computes the direction of the leak and overlays it on the live image.

4microphone array 1centre camera 4.3"touch display
Airleax L1

550 grams.
One hand. On site.

Take it out of the case, switch it on, scan. No setup, no training required.

Explore
01 / 03
Airleax L1 inside the open carrying case with its accessories
01Airleax L1 — field kit
01 — Why

A significant share of the air your compressor
produces is never used.

Leaks are inaudible, invisible, and quietly burn energy on every shift. Airleax L1 makes that loss measurable and provable — detect before the repair, verify after it.

See how it works
00 kHz

Ultrasonic detection range

0 hours

Continuous field use on one charge

0 g

Body you can carry in one hand

0 years

Manufacturer warranty

02 — Device

Every part of the body
serves exactly one purpose.

The display you read the measurement on at the front, the hardware that takes it at the back. Step through them below.

Front and back of the Airleax L1
    A
    1. A

      4.3" capacitive touch display

      Acoustic map, sound level and capture control on a single surface. Sized for gloved hands, with no secondary keypad to navigate the menu.

    2. B

      Four-element ultrasonic array

      Four microphones compute the direction of the source from the difference in arrival time. A single-microphone device tells you "there is a sound"; an array tells you "it is there".

    3. C

      Centre camera

      Sits at the exact centre of the array, so the acoustic data aligns with the real image on the same axis. You show the leak instead of describing it.

    4. D

      Dual LED lighting

      The places you hunt leaks are rarely well lit — boiler rooms, ceiling voids, under machinery. The light is built in.

    5. E

      Model and certification label

      Model code BHKTC-01, serial number, supply ratings and the CE mark are printed on the body. No need to open the device to log a service record.

    03 — How it works

    Three steps. No middleware,
    no middleman.

    LEAK DETECT MEASURE ARCHIVE
    The measurement chain, from leak to record
    1. 01

      Scan the line

      Point the back of the device at the suspect area and sweep slowly. The four microphones pick up the leak's ultrasonic signature in the 20–60 kHz band, and an on-screen arrow guides you to the centre of the source.

      • 20–60 kHz
      • Directional array
      • LED lighting
    2. 02

      Read four values at once

      Flow rate, distance, annual cost and sound level update live over the camera image. The highest dB and flow readings tell you the cursor is exactly over the leak.

      • Loss L/min
      • Distance cm
      • Cost /year
      • Sound dB
    3. 03

      Record, archive, verify

      Press the mechanical button once to capture, and add a note if you wish. Every measurement is stored in the Gallery with a date-time stamp. After the repair, scan the same point again and compare it with the earlier record.

      • Add notes
      • Gallery archive
      • USB Type-C

    Manual note. For the cost calculation to be accurate, set your distance to the leak point to 1 metre.

    — User manual

    The complete manual, right here.

    Setup, measurement, gallery management, warning messages and software updates — every page online. Click a page to enlarge.

    01–02 / 10 pages
    04 — Specifications

    Airleax L1

    The complete specification list as published in the user manual.

    AMeasurement

    Operating frequency
    20 – 60 kHz
    Display
    4.3" capacitive touch TFT

    BPower

    Power source
    7.2 V lithium-ion

    internal

    Operating time
    4.5 hours
    Charging time
    1.5 hours

    with the correct adapter and cable

    CInterface

    Connection
    USB Type-C
    Interface
    USB

    file transfer and software update

    DBody

    Dimensions
    210 × 108 × 79 mm

    including the sound cone

    Weight
    550 g
    Protection rating
    IP20

    EEnvironment

    Operating environment
    Indoor
    Operating temperature
    −5 °C … +50 °C
    Storage temperature
    −10 °C … +60 °C
    Altitude
    4000 m
    Maximum humidity
    < 95%

    non-condensing

    10 year manufacturer
    warranty

    Maintenance note. Contact with chemical cleaning agents and alcohol-based liquids must be avoided. Clean with a cloth dampened with water, then dry the device.

    CE FC IP20 MADE IN TÜRKİYE
    05 — In the box

    Impact-resistant carrying case.

    Device, manual, shoulder strap and accessories seated in moulded foam.

    Closed carrying case
    Locking, impact-resistant case 01
    Device inside the open case
    Moulded foam bed 02
    User manual inside the open case
    Manual and accessory compartment 03
    Airleax L1 Carry Case Launch Set
    06Airleax L1 Carry Case Launch Set
    06 — LAUNCH CAMPAIGN

    Airleax L1 Ultrasonic Leak Detector

    Detect costly leaks in your compressed air systems immediately. Order with launch campaign advantages.

    SPECIAL LAUNCH OFFER
    0 $ + VAT

    Same-Day Dispatch · 10-Year Warranty

    • Airleax L1 Ultrasonic Leak Detector Device
    • Shock & Water Resistant Heavy-Duty Carry Case
    • Fast Charger Adapter & Type-C Cable
    • 10-Year Manufacturer Warranty & Priority Service
    • Free On-Site Usage & Setup Training
    07 — Contact

    Let's measure the loss in your plant.

    Fill in the form for a demo, a quote or a dealership application.

    Quote form

    Your details are used only to respond to your request.

    We have received your request and will get back to you shortly.

    The map is provided by Google. Showing it requires accepting cookies.

    Hançerli Mahallesi Yalı Cami Sk. · Murathan Apt. No:3 Floor:2 No:6 · 55020 İlkadım / SAMSUN Open in Google Maps